| Applicant | Becker Mining Australia Pty Ltd |
| Address | 46 Glenwood Drive Thornton NSW 2322 Australia |
| Equipment | Contactor Module Type HPC-450-.-V5…-….-….-..-.. and Becker Mining Node Type BMN-. |
| Issue Number | 2 |
| Issue Date | 2018-01-30 |
| Status | Current |
| Manufacturer | Becker Mining Europe GmbH Walter-Becker-Strasse 1 D-66299 Friedrichsthal Germany Becker Mining Europe GmbH Gersdorffstr 29 45772 Marl Germany |
| Protection Type | Intrinsic safe ia ib |
| Group | I |
| Marking | [Ex ia ib] I (-20 °C ? Ta ? +85 °C), or [Ex ia ib] I & [Ex ia] I (-20 °C ? Ta ? +80 °C) for the Contactor Module with Becker Mining Node Type BMN-. |
| Test Report | FR/INE/ExTR08.0003/04, INERIS |
| Standards | IEC 60079-0:2011 and IEC 60079-11:2011 |
| Issued By | TestSafe Australia |