| Applicant | HAWE Hydraulics Australia |
| Address | U5 83-85 Montague Street, Wollongong, NSW 2500 Australia |
| Equipment | Twin solenoid 01 EX05 053x yzyz; 01 EX05 053H yzyz; 01 EX05 053K yzyz |
| Issue Number | 1 |
| Issue Date | 2024-03-12 |
| Status | Current |
| Manufacturer | Schienle Magnettechnik + Elektronik GmbH In Oberwiesen 3 Salem Neufrach 88682 Germany |
| Protection Type | Flameproof enclosure ‘d’ |
| Marking | Ex db I Mb |
| Test Report | DE/IBE/ExTR09.0002/02 - IBExU 38289 – TestSafe Australia |
| Standards | IEC 60079-0:2007 Ed 5, IEC 60079-1: 2007 Ed 6 |
| Issued By | Testsafe Australia |